| WH-1612 Model Triplex Piston Pump - Continuous Duty
Performance Data |
| Stroke,
in (mm): 12 (304.8) |
Gear
Ratio: 4.41 |
Rated
HP (kW): 1,600 (1,193) @ 120 spm |
STROKES
PER MINUTE |
120 |
110 |
100 |
90 |
80 |
70 |
MAXIMUM
INPUT HP (kW) RATING* |
1,600
(1,193) |
1,467
(1,094) |
1,333
(994) |
1,200
(895) |
1,067
(795) |
933
(696) |
LINER
SIZE
inches (mm) |
DISCHARGE
PSI (kg/cm²) # |
GAL
(L) PER REVOLUTION |
OUTPUT
GAL (L) PER MINUTE** |
7-1/2
(190.5) † |
2,987
(210.0) |
6.885
(26.060) |
826
(3,127) |
757
(2,867) |
688
(2,606) |
620
(2,346) |
551
(2,085) |
482
(1,824) |
7
(177.8) |
3,429
(241.1) |
5.998
(22.701) |
720
(2,724) |
660
(2,497) |
600
(2,270) |
540
(2,043) |
480
(1,816) |
420
(1,589) |
6-1/2
(165.1) |
3,997
(279.6) |
5.171
(19.574) |
621
(2,349) |
569
(2,153) |
517
(1,958) |
465
(1,762) |
414
(1,566) |
362
(1,370) |
6
(152.4) |
4,668
(328.2) |
4.406
(16.678) |
529
(2,002) |
485
(1,835) |
441
(1,668) |
397
(1,501) |
353
(1,334) |
308
(1,168) |
5-1/2
(139.7) |
5,555
(390.6) |
3.703
(14.014) |
444
(1,682) |
407
(1,542) |
370
(1,402) |
333
(1,261) |
296
(1,121) |
259
(981) |
5
(127.0) |
6,722
(472.6) |
3.060
(11.582) |
367
(1,390) |
337
(1,274) |
306
(1,158) |
275
(1,042) |
245
(927) |
214
(811) |
4-1/2
(114.3) |
7,500
(527.3) |
2.479
(9.381) |
297
(1,126) |
273
(1,032) |
248
(938) |
223
(844) |
198
(751) |
174
(657) |
*
Based on 90% mechanical efficiency **
Based on 100% volumetric efficiency
# Pressures greater than 5,000 psi require high-pressure
fluid ends
† Liner is induction-hardened, therefore liner life
is reduced |
 |
A - 2-3/8 (60.3)
B - 43-1/8 (1,095.4)
C - 40-5/8 (1,031.9)
D - 178-1/2 (4,533.9)
E - 70-1/2 (1,790.7)
F - 92-5/8 (2,352.7)
G - 53-1/2 (1,358.9)
H - 61-1/4
(1,558.8)
I - width:
2 (50.8),
- depth: 3/4
(19.0),
- length: 10
3/4 (273.1)
J - 8 1/2 (215.9)
inches
(millimeters) |
|
|
| |
|
|
|